SK08-T8
KNX sensor / 8-channel temperature controller for measuring and controlling up to eight temperatures.
The temperatures are measured with external temperature sensors (PT1000) (not included in the scope of delivery).
Different types of sensors can be connected.
For indoor, outdoor and damp room use IP54/65
Application: Temperature monitoring and control for heating/cooling purposes and logging

ETS-Application
DOWNLOAD ETS Application
Technical Data
SK08-T8 | |
---|---|
Supply voltage | KNX 21 .. 32V DC |
KNX Last | 10mA |
Operating/storage temperature Bus coupler | -25 .. +80°C / -25 .. +80°C |
Ambient humidity | 0 .. 100% non-condensing |
Dimensions | see diagram |
ETS-application | Arc_S8.knxprod / S8-T8 |
Protection class Bus coupler | IP54/65 |
Sensor PTxxxx | |
Measuring range depending on the measuring resistance | -50 .. +400°C |
resolution | ± 0,01°C |
accuracy | ± 0,3°C |
SK08-T8-PT100
KNX sensor / 8-channel temperature controller for measuring and controlling up to eight temperatures.
The temperatures are measured with external temperature sensors (PT100) (not included in the scope of delivery).
Different types of sensors can be connected.
For indoor, outdoor and damp room use IP54/65
Application: Temperature monitoring and control for heating/cooling purposes and logging

ETS-Application
DOWNLOAD ETS Application
Technical Data
SK08-T8 | |
---|---|
Supply voltage | KNX 21 .. 32V DC |
KNX Last | 10mA |
Operating/storage temperature Bus coupler | -25 .. +80°C / -25 .. +80°C |
Ambient humidity | 0 .. 100% non-condensing |
Dimensions | see diagram |
ETS-application | Arc_S8.knxprod / S8-T8 |
Protection class Bus coupler | IP54/65 |
Sensor PTxxxx | |
Measuring range depending on the measuring resistance | -50 .. +400°C |
resolution | ± 0,01°C |
accuracy | ± 0,3°C |
SK08-T8-PT500
KNX sensor / 8-channel temperature controller for measuring and controlling up to eight temperatures.
The temperatures are measured with external temperature sensors (PT500) (not included in the scope of delivery).
Different types of sensors can be connected.
For indoor, outdoor and damp room use IP54/65
Application: Temperature monitoring and control for heating/cooling purposes and logging

ETS-Application
DOWNLOAD ETS Application
Technical Data
SK08-T8 | |
---|---|
Supply voltage | KNX 21 .. 32V DC |
KNX Last | 10mA |
Operating/storage temperature Bus coupler | -25 .. +80°C / -25 .. +80°C |
Ambient humidity | 0 .. 100% non-condensing |
Dimensions | see diagram |
ETS-application | Arc_S8.knxprod / S8-T8 |
Protection class Bus coupler | IP54/65 |
Sensor PTxxxx | |
Measuring range depending on the measuring resistance | -50 .. +400°C |
resolution | ± 0,01°C |
accuracy | ± 0,3°C |